Imaging Location:
Dental Scan Ltd 
75 Harley Street
W1G 8QL
London

Scanner Used:
DEXIS OP 3D V17 (2021 MODEL)

Region Imaged:  
Both Jaws

Clinical Information:
Failing implant in LL5 region and possibly other implants in upper jaw.

Scanning Protocol:
16 x 8cm FOV, 0.25mm voxel size, 120 kVp, 5 mA, 7.4 seconds

Radiation Dose: 
Approximately 0.14 mSv


Xelis Dental Viewer (same price as i-CAT Vision Includes RAW DICOM files)
Allows you to plan your patient’s treatment easily, with a full implant library and free virtual implant placement capabilities. Our clinical team will prepare a study for you that includes: panoramic curve, custom reconstructed 3D, highlighting the inferior dental canal and image rotation according to the area of interest.

Findings:

Four endosseous implants are present.

The UR7 implant is approximately 30% osseointegrated and 33% inside the sinus cavity (Image 1).

The UR5 region shows an implant totally inside the sinus cavity (Image 2).

The LL5 implant has a broad radiolucent band around it, indicating peri-implantitis. This implant has penetrated the IDC (Image 3).

The LL6 implant has a radiolucent line between the implant and the bone. This may be due to peri-implantitis or beam hardening (Image 4).


Image 1.
The UR7 implant is approximately 30% osseointegrated and 33% inside the sinus cavity


Image 2.
The UR5 region shows an implant totally inside the sinus cavity


Image 3.
The LL5 implant has a broad radiolucent band around it, indicating peri-implantitis.
This implant has penetrated the IDC


Image 4.
The LL6 implant has a radiolucent line between the implant and the bone. This may be due to peri-implantitis or beam hardening

Thank you for your continued referrals.