Scanner Used and Location:
Dental Scan Ltd Manchester Branch
DEXIS OP 3D

Region Imaged:
Maxilla and Sinuses

Clinical Information:
Assessment of implants and implant planning in UL6 region.

Scanning Protocol:
10 x 8cm FOV, 0.2mm voxel size, 95 kVp, 3.2 mA, 12 seconds

Radiation Dose:
Approximately 0.15 mSv


Xelis Dental Viewer (same price as i-CAT Vision Includes RAW DICOM files)
Allows you to plan your patient’s treatment easily, with a full implant library and free virtual implant placement capabilities. Our clinical team will prepare a study for you that includes: panoramic curve, custom reconstructed 3D ,highlighting the inferior dental canal and image rotation according to the area of interest.

Findings:

5 dental implants are present at sites UR4, UR6, UR7, UL3 an UL5. There is reduced height around the implant at UR6 site. The UR4 implant is buccally positioned and exposed out from the buccal cortex (Image 2).

The UL5 implant is palatally positioned and exposed out from the palatal cortex (Image 3).

The UL3 is impacted in a mesio-angular direction. The crown is palatally positioned and contacts the roots of the UL1 and UL2. The root of the UL3 has an intimate relationship with the buccal cortex with the apex in contact with the nasal floor (Image 4).

The implant at site UL3 contacts the root of the impacted UL3 (Image 5).

Estimate bone volume measurements are provided for the UL6 site (Image 6).

Mild mucosal thickening is seen in the wall and floor of both sinuses. The left turbinates are enlarged (Image 7).


Image 1. Reconstructed Panoramic Image


Image 2


Image 3


Image 4

Image 5


Image 6


Image 7

Thank you for your continued referrals.

facebook linkedin instagram

Alex Woodham

Clinical Director

mobilePhone
+44 (0)20 7590 2020
emailAddress
alex@dental-scan.co.uk
website
https://dental-scan.co.uk/
address
Suite 17, 75 Harley Street, London, W1G 8QL
register book patient order report order conversion contact