Imaging Location:
Dental Scan Manchester
Suite 1, Trafalgar House
110 Manchester Rd, Altrincham, WA14 1NU

Scanner Used:
DEXIS OP 3D LX
(RRP £72,000 contact us for more info)

Clinical Information:
Recurrent pain associated with partial erupted and impacted LR8

Scanning Protocol:
8x7cm FOV, 0.2 voxels, 95kVp, 7mA, 11.7 seconds

Radiation Dose: 
Approximately 0.2 mSv


Xelis Dental Viewer (same price as i-CAT Vision Includes RAW DICOM files)
Allows you to plan your patient’s treatment easily, with a full implant library and free virtual implant placement capabilities. Our clinical team will prepare a study that includes: a panoramic curve, custom reconstructed 3D, highlighting the inferior dental canal, and image rotation according to the area of interest.

Findings:

  • The LR8 is partially unerupted and mesioangularly impacted against the LR7 (image 2).
  • The inferior dental canal passes through the mesial root, which splits into two roots, and is trapped between the two (image 2).
  • There is normal follicle space with no erosion of the distal root of the LR7 and mild loss of periodontal bone attachment.

Image 1.
Panoramic reconstruction

Image 2.

  • The LR8 is partially unerupted and mesioangularly impacted against the LR7
  • The inferior dental canal passes through the mesial root, which splits into two roots, and is trapped between the two

3D Reconstruction (Invivo)

Thank you for your continued referrals.

facebook linkedin instagram

Alex Woodham

Clinical Director

mobilePhone
+44 (0)20 7590 2020
emailAddress
alex@dental-scan.co.uk
website
https://dental-scan.co.uk/
address
Suite 17, 75 Harley Street, London, W1G 8QL
register book patient order report order conversion contact